OPERATING PARAMETERS
Unused parameter
Unused parameter
Unused parameter
Enable Save port position in memory at server shutdown (see RESP in screen error table).
if P076=0 at server shutdown, the port position is not saved and the position is always reset at next boot.
if P076=1 at server shutdown, the port position is saved in the memory and the position is not reset at next boot.
Warning: Perform a new motor stroke learning (P003) every time you change the parameter.
• 000: RESP active
• 001: RESP not active
Electronic positioning brake.
Caution: If active (P077=1), it is NECESSARY to set parameter P076 = 0 and install the mechanical stop (Art. AB/FM not supplied) 
on the rail in the open position.
• 000: not active
• 001: active
Conguration parameters dedicated to the expansion card NET_EXP (for a detailed description of the parameters, refer to the instruction manual).