SI-3
™
User’s Manual
15
• When a serial protocol is running and a command is
sent to the SI-3™, the SI-3™ does receive and perform
the requested function. However, the returned "OK"
may be inserted anywhere in the data stream and
the resulting action on the host computer can not
be guaranteed. Example: The protocol is sending out
"123.4" If a command is sent to the SI-3™, the response
may be 12OK3.4". For this reason it is recommended
that the "Stop" command be sent prior to any change
in serial protocol if a serial protocol has been selected
previously.
4.14 Start and Stop Output Buttons
These buttons are used to start and stop the continuously updated
serial protocol. Any congured Serial Protocol will resume periodic
data transmission after a power-cycle. The Stop command is used to
temporarily stop the periodic data transmission. This Stop state is not
retained after a power-cycle. The Clear Window button will clear the
output window.
4.15 Radar On/O button
The Radar On / O buttons turn the radar transmitter on and o.