SI-3
™
User’s Manual
28
Set target report
Send ASCII T,X,<CR>
Where ASCII value
X = 0 -> All targets,
X = 1 -> All directional,
X = 2 -> Towards,
X = 3 -> Away
Radar responds back with ASCII “OK”,<LF>,<CR>
Set horizontal Cosine Angle
Send ASCII H,XX,<CR>
Where XX = angle degrees in ASCII format
Radar responds back with ASCII “OK”,<LF>,<CR>
Set vertical Cosine Angle
Send ASCII V,XX,<CR>
Where XX = angle degrees in ASCII format
Radar responds back with ASCII “OK”,<LF>,<CR>
Set hold time
Send ASCII h,XXXX,<CR>
Where XXXX = milliseconds in ASCII format
Radar responds back with ASCII “OK”,<LF>,<CR>
Set update rate
(note: radar requires a power cycle for new values to be used)
Send ASCII U,X,<CR>
Where X = 0 -> 1*sec, X = 1 -> 2*sec, X = 2->5*sec, X=3->8*sec,X=4-
>change only, X=5->poll
Radar responds back with ASCII “OK”,<LF>,<CR>
Set sensitivity
Send ASCII S,X,<CR>
Where X = Sensitivity in ASCII format (0 to 9 allowed) 9 is
maximum value.
Radar responds back with ASCII “OK”,<LF>,<CR>