Reset to factory defaults
Send ASCII X,<CR> or ASCII x,<CR>
Radar will reset all congure items back to factory defaults and
save to ash.
Radar responds back with ASCII “FACTORY DEFAULTS”,<LF>,<CR> if
successful.
Save congure items to FLASH
Send ASCII F,<CR>
Radar responds back with ASCII “OK FLASH SAVED”,<LF>,<CR> on
success or ASCII “FLASH FAILURE”,<LF>,<CR> on failure.
Get congure data <not implemented – future release>
Send ASCII c,<CR>
Radar responds back with list of congurable items and values.