Configure the replacement SSD
Before you begin
If the existing iDRAC or IDPA vCetner Server session has been terminated, log in
again.
Complete the following steps after replacing an SSD.
Procedure
1. In the IDPA vCenter Server, select Hosts and Clusters > DPappliance-VSAN.
2. Select Manage > Settings > Virtual SAN > General.
3. Select Edit, and change the Add disks to storage value to Manual.
There are two Edit buttons on the screen. Use the top button, across from
Virtual SAN is Turned ON.
4. Select Manage > Settings > Virtual SAN > Disk Management.
5. Select the host where the failed drive was replaced.
6. Click the button to create a new disk group.
7. Select the SSD and the data disks.
8. Click OK.
9. Change Capacity Type to Flash.
10. Select Monitor > Virtual SAN > Resynching Components to monitor the
progress of the resynching operation and verify it completes successfully.
11. Select Edit, and change the Add disks to storage value to Automatic.
Configure the replacement HDD
Before you begin
If the existing IDPA vCenter Server session has been terminated, log in again.
Dell PowerEdge R630 Server FRUs
DELL EMC CONFIDENTIAL
Configure the replacement drive 39