Table 24 Chassis physical design (continued)
Parameter Specifications
Width 17.09 inches (434 mm)
Depth 18.11 inches (460 mm)
Chassis weight with factory-installed
components
21.7 lbs (9.86 kg)
Rack clearance required Front: 5 inches (12.7 cm)
Rear: 5 inches (12.7 cm)
Table 25 Environmental parameters
Parameter Specifications
Operating temperature 32° to 113°F (0° to 45°C)
Operating humidity 5 to 85% (RH), non-condensing
Storage temperature –40° to 158°F (–40° to 70°C)
Storage humidity 5 to 95%, non-condensing
Maximum thermal output 1153.265 BTU/hr
Maximum operational altitude 10,000 feet (3,048 meters)
Maximum non-operational altitude No performance degradation to 35,000 feet
(10,668 meters)
Shock Meets Bellcore Zone 4 earthquake
requirements (MIL-STD-810)
Table 26 AC power requirements
Parameter Specifications
Power supply 100–240 VAC 50/60 Hz
Maximum current draw per system 5.8 A @ 398.02 watts/100vac
2.9 A @ 398.02 watts/200vac
Maximum power consumption 460 Watts
Typical power consumption 338 Watts
Reliability MTBF 355.178 hours
System status
You can view S4048–ON status information using the light emitting diodes (LEDs).
LED displays
The S4048–ON includes LED displays on both the I/O Port and PSU side of the
chassis, as shown.
For LED information, see your third-party operating software documentation.
Dell S4048-ON Switch FRUs
DELL EMC CONFIDENTIAL
System status 77