Parameter Specifications
Maximum non-operational altitude 39,370 feet (12,000 meters)
Shock Dell EMC Spec SV0115
Table 12. Power consumption parameters
Parameter Specifications
Input voltage
AC: 100–240 VAC 50/60 Hz
DC: –40 VDC to –60 VDC
Input current without PoE
N2224X-ON: 2.46 Amps @ 110 VAC and 1.23 Amps @ 220 VAC
N2224PX-ON: 2.4 Amps @ 110 VAC and 1.2 Amps @ 220 VAC
N2248X-ON: 3.37 Amps @ 110 VAC and 1.69 Amps @ 220 VAC
N2248PX-ON: 3.3 Amps @ 110 VAC and 1.65 Amps @ 220
VAC
PSU configuration Main PSU
Total PoE budget
N2224PX-ON: up to 1080 W (1050 AC)
N2248PX-ON: up to 2160 W (1600 AC)
PoE output per port
N2224PX-ON: 24x2.5GBase-T Ports with 12 ports of 802.3at
(30W) PoE and 12 ports of 802.3bt Type-3 (60W) PoE
N2248PX-ON: 48x2.5GBase-T Ports 24 ports of 802.3at
(30W) PoE and 24 ports of 802.3bt Type-3 (60W) PoE
Table 13. AC power requirements
Parameter Specifications
Power supply
100–240 VAC 50/60 Hz
Maximum current draw per system 7A@110 VAC and 3.5 A@220 VAC
Maximum power consumption without PoE
N2224X-ON: 238 W maximum
N2224PX-ON: 238 W maximum
N2248X-ON: 326 W maximum
N2248PX-ON: 326 W maximum
Typical power consumption—switch operating with 100% traffic at
25°C
N2224X-ON: 115 W typical
N2224PX-ON:168 W typical
N2248X-ON: 138 W typical
N2248PX-ON: 210 W typical
Typical traffic/PoE consumption—switch operating with 50%
traffic and 50% PoE load at 25°C
N2224PX-ON:704 W typical
N2248PX-ON: 1370 W typical
Table 14. DC power requirements
Parameter Specifications
Minimum and maximum input voltage range –40 VDC to -60 VDC
Maximum current at full load with fan without PoE 550 W DC PSU:
N2224X-ON: 11.5 A @ 48 V
N2248X-ON: 11.5 A @ 48 V
1300 W DC PSU:
N2224PX-ON: 28 A @ 48 V
N2248PX-ON: 28 A @ 48 V
Specifications 55