2. Install the air shroud or install the GPU air shroud.
3. Follow the procedure listed in the After working inside your system.
Expansion cards and expansion card risers
NOTE: A system event entry is logged in the iDRAC Lifecycle Controller if an expansion card riser is not supported or
missing. It does not prevent your system from turning on. However, if a F1/F2 pause occurs with an error message,
see Troubleshooting expansion cards section in the Dell EMC PowerEdge Servers Troubleshooting Guide at www.dell.com/
poweredgemanuals.
Expansion card installation guidelines
Figure 112. Expansion card slot connectors
1. Riser 4 (slot 7 and slot 8)
2. Riser 3 (slot 4 and slot 5)
3. Riser 2 (slot 3 and slot 6)
4. Riser 1 (slot 1 and slot 2)
The following table describes the expansion card riser configurations:
Table 51. Riser configurations
Configurations Expansion
card risers
PCIe Slots Controlling
processor
height Length Slot width
Config0. with 4x
FH
R1B 1 and 2 Processor 1 Full height Half length x8 + x8
R4B 7 and 8 Processor 2 Full height Half length x8 + x8
Config1. with 6x
FH and 2x LP
R1B 1 and 2 Processor 1 Full height Half length x8 + x8
R2A 3 and 6 Processor 1 and
2
Low profile Half length x16 + x16