7. SAS cable(BP: J_SAS_A to MP: J_STORAGE1) 8. cable routing clip
Figure 93. Cable routing - 8 x 2.5 drive backplane with onboard SATA
1.
drive backplane 2. cable routing clip
3. backplane signal cable(BP: J_BP_SIG to MB: J_BP_SIG1) 4. backplane power cable(BP: J_BP_PWR_A1 to MB: J_BP1)
5. system board 6. SATA cable(BP: J_SAS_A0, J_SAS_B0 to MB: SATA_A,
SATA_B)
7. cable routing clip
SAS expander card
Removing the SAS expander card
Prerequisites
1. Follow the safety guidelines listed in Safety instructions on page 71.
2. Follow the procedure listed in Before working inside your system on page 72.
3. Remove the cooling shroud.
4. Remove the cooling fan assembly.
5. Remove the backplane cover.
6. Disconnect the SAS cables from the SAS expander card.
Steps
1. Using Philips #2 screwdriver, loosen the screws that secure the SAS expander card to the expander card tray.
2. Pull the SAS expander card to disengage the connectors on SAS expander from the SAS connectors on backplane.
142