Powering on procedures for PowerStore node
This section includes the following procedures:
Power on a PowerStore T model node using a service script on page 114
Power on a PowerStore T model node by reseating the node on page 114
Power on a PowerStore X model node using a service script on page 114
Power on a PowerStore X model node by reseating the node on page 115
Power on a PowerStore T model node using a service script
Prerequisites
Obtain the following information:
Management IP address of the appliance that contains the node. In PowerStore Manager, go to Settings > Networking
> Networking IPs > Management. Review the Management IPs table to identify the management IP address associated
with the appliance.
Service account credentials
About this task
Use the following procedure to power on (power up) a PowerStore T model node in scenarios such as:
You are remote and cannot reseat the node.
Node was not removed from the chassis.
Embedded module, I/O module, and 4-port card were replaced.
Steps
1. Launch an SSH client, and connect to the appliance using the management IP address. Since only the peer node is powered
on, you are connected directly to the peer node of the appliance.
2. Enter the username and password that is associated with the service account, and log in.
3. Run the following command:
svc_node power_on
4. Wait for the node to power on.
Power on a PowerStore T model node by reseating the node
About this task
Use the following procedure to power on (power up) a PowerStore T model node when it was removed from the chassis:
Steps
1. Reseat the node into the chassis.
The node will power on automatically.
2. Reconnect the power cable.
3. Wait for the node to complete powering on.
Power on a PowerStore X model node using a service script
Prerequisites
Obtain the following information:
Address of the VMware vCenter server associated with the appliance
Associated vCenter server account credentials
Management IP address of the appliance that contains the node
Service account credentials