Figure 108. Releasing the top cover
2. Lift the top cover upward, and remove it from the node.
Figure 109. Removing the top cover
Transfer parts from the faulted node to the replacement node
Transfer the following components from the faulted node to the corresponding locations in the replacement node.
To help ensure the correct placement in the enclosure, transfer only one component at a time.
NOTE: Confirm that all parts are fully seated before inserting the node into the base enclosure.
NOTE: Do not add any components while the node is powering on.
● Transfer the power supply.
● Transfer the I/O modules and fillers.
● Transfer the embedded module without removing the 4-port card.
● Transfer the internal M.2 boot modules without removing them from the adapters.
● Transfer DIMMs.
NOTE: Move DIMMs one at a time from the faulted node to the same slot on the replacement node.
● Transfer internal fans.
Base enclosure service procedures
87