Figure 24. Installing a 2.5" drive
5. If you are installing an NVMe NVRAM drive, push the latch cover into place.
The activity light flashes to indicate that the spin-up sequence has begun.
Verify the operation of an added drive
Steps
1. From PowerStore Manager, select Hardware.
2. Select the appliance where you added the drive.
3. On the Components card, under Drives, expand BaseEnclosure and select the drive.
The status of the drive should read Healthy. If the status is still Faulted, wait a few minutes and refresh PowerStore
Manager. If the status does not change, ensure that the drive is correctly seated, or contact your service provider.
Replace a power supply
Take the following actions to remove the faulted power supply and install the replacement power supply into the system.