Figure 39. Embedded module LEDs
Table 3. Embedded module LEDs
LED Location State Description
Embedded module power Amber Embedded module has faulted.
Off No fault has occurred, normal operation.
Ethernet port link Green Link established.
Off No link established.
Ethernet port activity Amber blinking Port activity.
Off No port activity.
SAS port and activity link Blue SAS port link is up.
Off No link established.
Port link Green Link up with high speed.
Amber Link up with degraded speed.
Off Link down.
Node fault Amber Fault has occurred.
Amber or blue
blinking
System is booting.
Blue and amber
alternating (green
for 3 seconds)
System not initialized. A management IP
address has not been assigned.
Blue and amber
alternating at one
second intervals
Node in Service Mode.
Off No fault has occurred, normal operation.
Node power Green Node is on (main power).
Green blinking Node is initializing a serial over LAN
session (Standby Mode).
Off Node is off.
Unsafe to remove White Do not remove the node. Improper
removal could cause data loss.
Off Safe to remove the embedded module
when the embedded module has been
properly prepared.
Base enclosure service procedures 43