EasyManua.ls Logo

Dell Networking 7048 - Page 46

Dell Networking 7048
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44 System Firmware Version 5.1.0.1
Summary
User Impact
Resolution
Affected
Platforms
PFC sends packet after quanta
extension received.
This can cause FCOE failures when using
PCM8024-k as a transit switch between
some switches.
Switch no longer sends
packet after quanta
extension received.
PCM8024-k
CLI command "show ipv6
interface" does not paginate
correctly.
A large number of interfaces cause
information to scroll off the viewing area.
Fixed the pagination for the
command.
All Platforms
MOTD Banner appears at the
wrong time.
MOTD and Login Banner is not visible
before login for SSH users.
Fixed the banner processing
function.
PCM6220
Summertime function running
early.
The summertime function resets the time
on the wrong week.
Corrected the function that
returns the day of the week
to account for particular
months and leap years.
All Platforms
Switch does not save complete
MST VLAN configuration.
The correct configuration was not being
saved if there are more than 1K VLANs in
a single MST instance.
Corrected the VLAN
configuration buffer size.
PC8024
PCM8024
Switch failed to generate new
RSA/DSA crypto keys.
“Failed to generate RSA key.” message
was produced and keys were not
generated.
Fixed error condition when
generating keys.
PCM8024
Banner MOTD configuration
changes after reload.
After reload a MOTD with an embedded!
Character will be truncated.
Fix the MOTD engine to not
ignore the leading ‘!
character.
PCM8024
VLANs can get removed from
running-config.
Creating vlans, assigning ports using the
vlan membership detail page causes
removal from running-config.
Corrected default VLAN
checks when updating
VLAN information.
All Platforms
Console session locks up. CLI command "show interface detail port-
channel1" locks up console session.
Corrected buffer overflow
during "show interfaces
detail" execution.
All Platforms
Fiber diagnostics reporting
incorrect port type.
When running fiber diagnostics, Ports 5, 7,
8, 13, 15, 16 report to be fiber ports and
not copper ports.
Fixed reporting of valid
copper ports.
PC8024
BROADCOM-REF-MIB
reporting incorrect values.
Incorrect Model numbers and revision date
in BROADCOM-REF-MIB dellref.my
Model numbers which are
described in dellref.my are
corrected.
PC70XX
Switch crashes when full vlan
range assigned to MST
regions.
When the full range of VLAN instances is
assigned to a MST region the switch
crashes.
Corrected VLAN instance
buffer overflow.
PCM6220
Config Wizard causes iSCSI
error messages.
Using the config wizard to setup the
PC8024 causes iSCSI error messages.
Correct the handling of
iSCSI admin mode.
PC8024
SSH configuration not restored
after reboot.
The 'ip ssh protocol 2' is not being
included in the running configuration.
Corrected the ability to
place 'ip ssh protocol 2' in
the running-config.
All Platforms
1GB link being negotiated on
10GB Intel X520-KX4
Some internal links on the Modular
switches will not link at 10Gb.
Corrected the port mapping
to allow proper port
configuration.
PCM8024
PCM8024-k
No message logged for "Max
number of SSH login sessions
exceeded"
When the Max number of SSH sessions is
reached no error is logged.
Added an error message.
All Platforms
VLAN web page not updating. When VLANs are removed using the web,
the GUI doesn’t display the ports that are
members of the VLAN.
Corrected the fetch of
current VLAN data.
All Platforms

Other manuals for Dell Networking 7048

Related product manuals