41 Stacking Dell Networking Switches: N4032, N4032F, N4064, N4064F
Use the freed cables or new cables to connect the two switches together that were previously adjacent to
the switch being removed. Since there are multiple interface and cable types supported for stacking, a
different set of cables may be required to make this connection.
19 21 23
20 22 24
17
18
11 13 15
12 14 16
9
10
3 5 7
4 6 8
1
2
ACTLNK
2 864
1 753
10 161412
9 151311
18 242220
17 232119 ACTLNK
ACT
LNK
ACT
LNK
7 9 151311 17 232119 25 312927 33 393735 41 474543 ACTLNK
1 2
2 864 10 161412 18 242220 26 323028 34 403836 42 484644
10GBASE-T MODULE
LNK ACT
SWITCH REMOVED
FROM STACK
Removal of a stack unit Figure 14
Removal of a stack unit results in one or more freed cables. In this example, a single cable (red) that was
used to link Unit 2 to Unit 3 has been freed up. The other cable that was going from Unit 1 to Unit 2, is
now used to connect Unit 1 to Unit 3, using the same stack ports that were used initially to once again
complete the ring topology. Move this cable to complete the stack unit removal process.
2.5.1.2 Validation
To validate the stack unit has been removed and that the remaining stack members are still intact, type the
show switch command.
console#show switch
Management Standby Preconfig Plugged-in Switch Code
SW Status Status Model ID Model ID Status Version
--- ---------- --------- ------------- ------------- ------------- -------
1 Mgmt Sw N4032 N4032 OK 6.0.1.3
2 Unassigned N4032F Not Present 0.0.0.0
3 Stack Mbr Oper Stby N4064 N4064 OK 6.0.1.3