EasyManuals Logo

Dell Networking N4032 User Manual

Dell Networking N4032
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
55 Stacking Dell Networking Switches: N4032, N4032F, N4064, N4064F
3 Managing the standby unit
If the Master unit fails or is taken offline, a Standby unit automatically takes place as Master. During this
time there is no more than a 50 ms interruption in unicast connectivity.
The commands below are used to manage your Standy unit.
3.1.1 Command-line interface method
To find out which unit is currently in Standby status, run the show switch command.
console#show switch
Management Standby Preconfig Plugged-in Switch Code
SW Status Status Model ID Model ID Status Version
--- ---------- --------- ------------- ------------- ------------- -------
1 Mgmt Sw N4032 N4032 OK 6.0.1.3
2 Stack Mbr Oper Stby N4064 N4064 OK 6.0.1.3
3 Stack Mbr N4032F N4032F OK 6.0.1.3
The
Standby Status
column shows which unit is in Standby mode. There are two standby modes:
Oper
Stby
and
Cfg Stby
.
Oper
Stby is selected automatically by the Master during stack creation. If the
administrator decides to select a different unit to be Standby, then it is labeled
Cfg
Stby. Both Standby
modes work identically.
In this example, unit 2 is the stack standby for the Master unit. To change the standby to a different unit,
use the standby x command. Verify the change with the show switch command.
console(config-stack)#standby 3
console#show switch
Management Standby Preconfig Plugged-in Switch Code
SW Status Status Model ID Model ID Status Version
--- ---------- --------- ------------- ------------- ----------- -------
1 Mgmt Sw N4032 N4032 OK 6.0.1.3
2 Stack Mbr N4064 N4064 OK 6.0.1.3
3 Stack Mbr Oper Stby N4032F N4032F OK 6.0.1.3
This method cannot be used to assign the current Stack Master to the Standby role and results in an error.
In the event there is a need to change the role of the Master or make the Standby the Master, use the
initiate failover command from the Command Line Interface. This command results in a warm
restart of the stack Master, triggering the Standby unit to take over as a new Master switch.

Other manuals for Dell Networking N4032

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Networking N4032 and is the answer not in the manual?

Dell Networking N4032 Specifications

General IconGeneral
Rack Units1U
LayerLayer 3
ManageableYes
StackableYes
MAC Address Table Size32, 000 entries
Jumbo Frame SupportYes
Jumbo Frame Size9216 bytes
Input Voltage100-240 VAC
Operating Temperature0°C to 45°C (32°F to 113°F)
Uplink Ports8 x 10 Gigabit Ethernet 10GBASE-T
Power SupplyDual, hot-swappable
Operating Humidity10% to 90% non-condensing

Related product manuals