EasyManua.ls Logo

Dell OptiPlex 3060 Tower - Page 74

Dell OptiPlex 3060 Tower
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 4. Amber LED blinking failures (continued)
Amber LED state White LED state System state Notes
2 2 Bad MB, PSU or cabling Bad MBD, PSU or PSU
cabling - Rows B, C and D of
table 12.4 SIO spec [40]
2 3 Bad MBD, DIMMS, or CPU Bad MBD, DIMMS or CPU -
Rows F and K from table 12.4
of SIO spec [40]
2 4 Bad coin cell Bad coin cell - Row M of table
12.4 in SIO spec [40]
Table 5. States Under Host BIOS Control
Amber LED state White LED state System state Notes
2 5 BIOS state 1 BIOS Post code (Old LED
pattern 0001) Corrupt BIOS.
2 6 BIOS state 2 BIOS Post code (Old LED
pattern 0010) CPU config or
CPU failure.
2 7 BIOS state 3 BIOS Post code (Old LED
pattern 0011) MEM config
in process. Appropriate mem
modules detected but failure
has occurred.
3 1 BIOS state 4 BIOS Post code (Old LED
pattern 0100) Combine PCI
device config or failure with
video sub sytem config or
failure. BIOS to eliminate 0101
video code.
3 2 BIOS state 5 BIOS Post code (Old
LED pattern 0110) Combine
storage and USB config or
failure. BIOS to eliminate 0111
USB code.
3 3 BIOS state 6 BIOS Post code (Old LED
pattern 1000) MEM config, no
memory detected.
3 4 BIOS state 7 BIOS Post code (Old
LED pattern 1001) Fatal
Motherboard error.
3 5 BIOS state 8 BIOS Post code (Old LED
pattern 1010) Mem config,
modules incompatible or
invalid config.
3 6 BIOS state 9 BIOS Post code (Old
LED pattern 1011) combine
"Other pre-video activity and
resource configuration codes.
BIOS to eliminate 1100 code.
3 7 BIOS state 10 BIOS Post code (Old LED
pattern 1110) Other pre-post
activity, routine subsequent to
video init.
74 Troubleshooting

Table of Contents

Related product manuals