PowerEdge R415 Technical Guide
Feature
Non-Redundant Power
Supply
Redundant Power Supply
ambient operating range, the
inrush current may reach 25A
per power supply for 10ms or
less.
ambient operating range, the
inrush current may reach 25A
per power supply for 10ms or
less.
Hot-plug Capability
No
Yes
Output Power
480W
500W
Efficiency
20% to 100% Load
8285% @115VAC
8285% @ 230VAC
8690% @115VAC
8892% @ 230VAC
Energy Star Certification &
Compliance
80+ Bronze
80+ Silver
1
Does not include the power supply handle or ejection tab.
4.3 Heat Dissipation
Table 5 details heat dissipation for the PowerEdge R415.
Table 5. Heat Dissipation
Description
Non Redundant Power Supply
Redundant Power Supply
Wattage
480W
500W
Voltage
100240VAC, 5060Hz, 7.53.8
100240VAC, 5060Hz, 7.53.8
Heat Dissipation
1637 BTU/hr maximum
1706 BTU/hr maximum
4.4 Environmental Specifications
Table 6 summarizes the environmental specifications for the PowerEdge R415.
Table 6. Environmental Specifications
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum temperature
gradation of 10°C per hour
Note: For altitudes above 2950 feet, the maximum operating
temperature is derated 1°F/550 ft.
Storage
-40° to 65°C (-40° to 149°F) with a maximum temperature
gradation of 20°C per hour
Relative Humidity
Operating
20% to 80% (noncondensing) with a maximum humidity gradation
of 10% per hour
Storage
5% to 95% (noncondensing) with a maximum humidity gradation
of 10% per hour
Maximum Vibration
Operating
0.26Grms at 5350Hz in operational orientations
Storage
1.87Grms at 10500Hz in all orientations