Next steps
1. Install the air shroud.
2. Follow the procedure listed in After working inside your system.
Expansion cards and expansion card risers
NOTE: A system event entry is logged in the iDRAC Lifecycle Controller if an expansion card riser is not supported or
missing. It does not prevent your system from turning on. However, if a F1/F2 pause occurs with an error message,
see Troubleshooting expansion cards section in the Dell EMC PowerEdge Servers Troubleshooting Guide at www.dell.com/
poweredgemanuals.
Expansion card installation guidelines
The following table describes the supported expansion cards:
Table 17. Expansion card riser configurations
Expansion card riser PCIe slots on the
riser
Processor
connection
Height Length Slot
width
Riser-1B (2U riser) Slot 2 Processor 1 Full Height Full Length x16
Riser-1B (2U riser) Slot 3 Processor 1 Full Height Full Length x16
Riser-1A (low profile
riser right)
Slot 2 Processor 1 Low Profile Half Length x16
Riser-2 (low profile
riser left)
Slot 3 Processor 1 Low Profile Half Length x16
NOTE: The expansion-card slots are not hot-swappable.
The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion
cards with the highest priority should be installed first using the slot priority indicated. All the other expansion cards should be
installed in the card priority and slot priority order.
Table 18. Riser configurations: No riser – CPU
Card Type Slot Priority Maximum number of cards
LOM riser ; 2x1G BCM5720L (FXN) 1 1
LOM riser ; 2x10G BCM57416 (BASeT/
SFP+) (FXN)
1 1
LOM riser ; 2x25G (Broadcom) 1 1
GPU: Nvidia T4 16GB 5, 4 2
NVMe PCIe SSD 5, 4 2
Mellanox 100G (CX5/CX6 H100) 4, 5 2
Mellanox 25G (CX4LX DP/CX5 DP) 5, 4 2
Emulex (FC32 SP/DP) 4, 5 2
Emulex (FC16 SP/DP) 5, 4 2
Emulex (HBA FC32 1P S28) 5, 4 2
Qlogic (HBA FC32 SP/DP) 4, 5 2
Qlogic (HBA FC16 SP/DP) 5, 4 2
Qlogic 10G (SFP DP) 5, 4 2
Installing and removing system components 69