28 About Your System
E1414 CPU
#
temp
exceeding
range. Check
CPU heatsink.
Specified processor is out
of acceptable temperature
range.
Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Processor(s)" and
"Troubleshooting System
Cooling Problems."
E1418 CPU
#
not
detected.
Check CPU is
seated
properly.
Specified processor is
missing or bad, and the
system is in an
unsupported
configuration.
Ensure that the specified
microprocessor is
properly installed. See
"Troubleshooting the
Processor(s)."
E141C Unsupported
CPU
configuration.
Check CPU or
BIOS revision.
Processors are in an
unsupported
configuration.
Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system’s
Getting Started Guide.
E141F CPU
#
protocol
error. Power
cycle AC.
The system BIOS has
reported a processor
protocol error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E1420 CPU Bus parity
error. Power
cycle AC.
The system BIOS has
reported a processor bus
parity error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
E1422 CPU
#
machine
check error.
Power cycle
AC.
The system BIOS has
reported a machine check
error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
Table 1-1. LCD Status Messages (continued)
Code Text Causes Corrective Actions
book.book Page 28 Tuesday, September 15, 2009 10:08 AM

Table of Contents

Other manuals for Dell PowerEdge T610