About Your System 29
E1610 Power Supply
#
(
###
W)
missing. Check
power supply.
Specified power supply
was removed or is missing
from the system.
See "Troubleshooting
Power Supplies."
E1614 Power Supply
#
(
###
W) error.
Check power
supply.
Specified power supply
has failed.
See "Troubleshooting
Power Supplies."
E1618 Predictive
failure on
Power Supply
#
(
###
W). Check
PSU.
A power supply fan failure,
an over-temperature
condition, or a power
supply communication
error has caused the
predictive warning of an
impending power supply
failure.
See "Troubleshooting
Power Supplies."
E161C Power Supply
#
(
###
W) lost
AC power.
Check PSU
cables.
Specified power supply is
attached to the system,
but it has lost its AC
input.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies."
E1620 Power Supply
#
(
###
W) AC
power error.
Check PSU
cables.
Specified power supply's
AC input is outside of the
allowable range.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies."
E1624 Lost power
supply
redundancy.
Check PSU
cables.
The power supply
subsystem is no longer
redundant. If the
remaining power supply
fails, the system will shut
down.
See "Troubleshooting
Power Supplies."
Table 1-1. LCD Status Messages (continued)
Code Text Causes Corrective Actions
book.book Page 29 Tuesday, September 15, 2009 10:08 AM