About Your System 31
E1712 PCI system
error on Bus
##
Device
##
Function
##
The system BIOS has
reported a PCI system
error on a component that
resides in PCI
configuration space at bus
##, device ##, function
##.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards."
E1714 Unknown error.
Review & clear
SEL.
The system BIOS has
determined there has been
an error in the system, but
is unable to determine its
origin.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help."
E1715 Fatal I/O
Error. Review
& clear SEL.
The system BIOS has
determined there has been
a fatal error in the system.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help."
E1716 Chipset IERR
Bus
##
Dev
##
Function
##
.
Review & clear
SEL.
The system BIOS has
reported a chipset internal
error that resides in bus
##, device ##, function
##.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help."
Table 1-1. LCD Status Messages (continued)
Code Text Causes Corrective Actions
book.book Page 31 Tuesday, September 15, 2009 10:08 AM