32 About Your System
E1717 CPU
#
internal
error. Review
& clear SEL.
The system BIOS has
determined that the
specified processor has
had an internal error.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help."
E171F PCIe fatal
error on Bus
##
Device
##
Function
##
The system BIOS has
reported a PCIe fatal error
on a component that
resides in PCI
configuration space at bus
##, device ##, function
##.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards."
E1810 Hard drive
##
fault. Review
& clear SEL.
The specified hard drive
has experienced a fault.
See "Troubleshooting a
Hard Drive."
E1812 Hard drive
##
removed. Check
drive.
The specified hard drive
has been removed from
the system.
Information only.
E1A14 SAS cable A
failure. Check
connection.
SAS cable A is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help."
E1A15 SAS cable B
failure. Check
connection.
SAS cable B is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help."
Table 1-1. LCD Status Messages (continued)
Code Text Causes Corrective Actions