Revision April 2009 7-63
P2 - 36
POV1 Moving Speed Setting of 1st Position Communication Addr.: 0224H
Default: 1000 Related Section:
Applicable Control Mode: Pr Section 6.2.2
Unit: r/min
Range: 1 ~ 5000
Settings:
When setting value of P2-36 to P2-43 is higher than 3000 r/min, please set the setting value of
P1-55 to its maximum value.
P2 - 37
POV2 Moving Speed Setting of 2nd Position Communication Addr.: 0225H
Default: 1000 Related Section:
Applicable Control Mode: Pr Section 6.2.2
Unit: r/min
Range: 1 ~ 5000
Settings:
Please refer to P2-36.
P2 - 38
POV3 Moving Speed Setting of 3rd Position Communication Addr.: 0226H
Default: 1000 Related Section:
Applicable Control Mode: Pr Section 6.2.2
Unit: r/min
Range: 1 ~ 5000
Settings:
Please refer to P2-36.
P2 - 39
POV4 Moving Speed Setting of 4th Position Communication Addr.: 0227H
Default: 1000 Related Section:
Applicable Control Mode: Pr Section 6.2.2
Unit: r/min
Range: 1 ~ 5000
Settings:
Please refer to P2-36.