Chapter 7 Servo Parameters|ASDA-A&A+ Series 
7-14    
Revision April 2009 
Speed Control 
Control 
Mode 
Parameter  Name  Function  Default Unit
Pt  Pr  S  T 
Related 
Section of 
User 
Manual 
P1-01● 
CTL  Control Mode and Output Direction  0 
pulse
r/min
N-m
{  {  {  { 
6.1 
P1-02▲ 
PSTL  Speed and Torque Limit  0  N/A
{  {  {  { 
6.6 
P1-46▲ 
GR3  Encoder Output Pulse Number  1  pulse
{  {  {  { 
--- 
P1-55  MSPD  Maximum Speed Limit 
rated 
speed
r/min
{  {  {  { 
--- 
1st ~ 3rd Speed Command 
P1-09 
~ P1-11 
SP1 ~ 
3 
1st ~ 3rd Speed Limit 
100 ~ 
300 
r/min  
{  { 
6.3.1 
1st ~ 3rd Torque Command 
P1-12  
~ P1-14 
TQ1 ~ 
3 
1st ~ 3rd Torque Limit 
100 % 
{  {  {  { 
6.6.2 
P1-40▲ 
VCM 
Max. Analog Speed Command or 
Limit 
rated 
speed
r/min  
{  { 
6.3.4 
P1-41▲ 
TCM 
Max. Analog Torque Command or 
Limit 
100  % 
{  {  {  { 
--- 
P2-63  TSCA  Proportion Value Setting  0  times
{  {  { 
 --- 
P2-64  TLMOD  Torque Limit Mixed Mode  0  N/A
{  {  { 
 --- 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Explanation of symbols (marked after parameter) 
(★) Read-only register. 
(▲)  Parameter cannot be set when Servo On (when the servo drive is enabled). 
(●)  Parameter is effective only after the servo drive is restarted (after switching power off and on). 
(■)  Parameter setting values are not retained when power is off. 
Call 1(800)985-6929 for Sales
Call 1(800)985-6929 for Sales