Delta Electronics VFD007M43B Specifications

General IconGeneral
SeriesVFD-M
Horsepower1 HP
Output Power0.75 kW
Output Frequency0-400 Hz
Braking UnitBuilt-in
Control MethodV/F control, Sensorless Vector Control
Communication InterfaceRS-485
Protection FeaturesOvercurrent, Overvoltage
Input Voltage3-phase 380 ~ 480 VAC

Summary

Chapter 2 Installation and Wiring

2.1 Basic Wiring Diagram

Presents the fundamental circuit diagram for connecting the AC motor drive, motor, and optional components.

Chapter 3 Keypad and Start Up

Chapter 4 Parameters

4.1 Summary of Parameter Settings

Provides a comprehensive overview of the drive's parameters, their explanations, settings, and factory defaults.

4.3 Description of Parameter Settings

Offers detailed explanations and examples for key parameters, clarifying their function and usage.

Chapter 5 Troubleshooting

5.1 Over Current (OC)

Outlines troubleshooting steps for over-current faults, including checks for wiring, load, and acceleration/deceleration times.

5.2 Ground Fault

Provides a flowchart for diagnosing and resolving ground fault issues, including checking output grounding and potential drive malfunctions.

5.3 Over Voltage (OV)

Details troubleshooting steps for over-voltage faults, focusing on voltage specifications, DC bus voltage, and deceleration parameters.

5.4 Low Voltage (Lv)

Guides users through troubleshooting low voltage faults, checking input power, components, and load conditions.

5.5 Over Heat (OH1)

Addresses over-heating issues by checking heat sink temperature, cooling fans, load, and ambient conditions.

5.6 Overload

Troubleshooting steps for overload conditions, including checking settings, load, and motor capacity.

5.8 Phase Loss (PHL)

Guides on diagnosing phase loss faults by checking wiring, terminal tightness, and input voltage balance.

5.9 Motor cannot Run

Provides a comprehensive flowchart for troubleshooting motor run issues, covering display, faults, commands, and wiring.

5.10 Motor Speed cannot be Changed

Troubleshooting steps for issues where motor speed cannot be adjusted, checking frequency settings and input signals.

5.11 Motor Stalls during Acceleration

Addresses motor stalling during acceleration by examining acceleration time, load inertia, input voltage, and torque compensation.

5.12 The Motor does not Run as Expected

Troubleshooting steps for unexpected motor behavior, checking parameter settings and load conditions.

Chapter 6 Fault Code Information and Maintenance

6.1 Fault Code Information

Details various fault codes detected by the drive's diagnostic system and their corresponding corrective actions.