Chapter 8 Servo Parameters
8-24 Revision January 2011
Speed Control
Control Mode
Parameter Name Function Default
Unit
PT PR S T
Related
Section
P1-01
CTL
Control Mode and Output
Directio
n
0
pulse
r/min
N-M
O
O O O 6.1
P1-02
PSTL Speed and Torque Limit 0 N/A
O
O O O 6.6
P1-46
GR3 Encoder Output Pulse Number 1 pulse
O
O O O -
P1-55 MSPD Maximum Speed Limit rated
r/min
O
O O O -
P1-09 ~
P1-11
SP1 ~ 3 1st ~ 3rd Speed Command
1000
~
3000
0.1
r/min
O O 6.3.1
P1-12 ~
P1-14
TQ1 ~ 3 1st ~ 3rd Torque Limit 100 % O
O O O 6.6.2
P1-40
VCM
Max. Analog Speed Command
or Lim
it
rated
r/min
O O 6.3.4
P1-41
TCM
Max. Analog Torque Command
or Lim
it
100 % O
O O O -
P1-76 AMSPD
Max. Rotation Speed of Encoder
Outp
ut
5500
r/min
O
O O O -
Explanation of symbols (marked after parameter)
(
) Read-only register.
() Parameter cannot be set when Servo On (when the servo drive is enabled).
(
) Parameter is effective only after the servo drive is restarted (after switching power off and
on).
(
) Parameter setting values are not retained when power is off.