EasyManua.ls Logo

Delta Electronics VFD007M43B

Delta Electronics VFD007M43B
173 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A Specifications|
Revision May 2008, ME14, SW V3.04 A-3
General Specifications
Keypad
Setting by
Frequency
Setting
External
Signal
Potentiometer-5KΩ/0.5W, 0 to +10VDC, 4 to 20mA RS-485
interface; Multi-Function Inputs 0 to 5 (7 steps, Jog, up/down)
Keypad Set by RUN, STOP
Operation
Setting
Signal
External
Signal
M0 to M5 can be combined to offer various modes of operation,
RS-485 serial interface (MODBUS).
Multi-Function Input Signal
Multi-step selection 0 to 7, Jog, accel/decel inhibit, first to forth
accel/decel switches, counter, PLC operation, external Base
Block (NC, NO), auxiliary motor control is invalid, selections,
driver reset, UP/DOWN key settings, sink/source selection
Multi-Function Output
Indication
AC drive operating, frequency attained, non-zero, base block,
fault indication, local/remote indication, PLC operation indication,
auxiliary motor output, driver is ready, overheat alarm, emergency
stop
Operating Characteristics
Analog Output Signal Analog frequency/current signal output.
Alarm Output Contact 1 Form C contact or open collector output
Operation Functions
AVR, S-Curve, over-voltage, over-current stall prevention, fault
records, adjustable carrier frequency, DC braking, momentary
power loss restart, auto tuning, frequency limits, parameter
Lock/Reset, vector control, counter, PID Control, PLC, MODBUS
communication, reverse Inhibition, abnormal reset, abnormal re-
start, digital frequency output, sleep/revival function, 1st/2nd
frequency source selections
Protection Functions
Self-testing, over voltage, over current, under voltage, overload,
overheating, external fault, electronic thermal, ground fault.
Display Keypads
6-key, 4-digit, 7-segment LED, 4 status LEDs, master frequency,
output frequency, output current, custom units, parameter values
for setup, review and faults, RUN, STOP, RESET, FWD/REV
Built-in Brake Chopper Built-in for all models
Protection Level IP20
Pollution Degree 2
Installation Location
Altitude 1,000 m or lower, keep from corrosive gasses, liquid and
dust
Ambient Temperature
-10
o
C to 40
o
C (-10
o
C to 50
o
C without blind plate)
Non-Condensing and not frozen
Storage/ Transportation
Temperature
-20
o
C to 60
o
C
Ambient Humidity Below 90% RH (non-condensing)
Enviromental Conditions
Vibration 9.80665m/s
2
(1G) less than 20Hz, 5.88m/s
2
(0.6G) at 20 to 50Hz
Approvals
Note: Do not attempt to connect a single-phase power source to a three-phase models drive.
However it is acceptable to connect two wires of a three-phase power source to a single-
phase drive.