Chapter 8  Parameters  ASDA-A2 
8-170     Revision February, 2017 
P5-19    TBS  E-Cam Curve Scaling 
Address: 0526H 
0527H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: - 
 
Default: 
1.000000 
 
Control 
Mode: 
PR 
 
Unit: 
0.000001 times, which is 1 / (10^6) 
 
Range: 
-2147.000000 ~ +2147.000000 
 
Data Size: 
32-bit 
 
Format: 
DEC 
 
Example: 
1100000 = 1.1 times 
 
Settings: 
(It will be provided after firmware version V1.017) 
This parameter is used to magnify or minify the E-Cam table without 
changing its setting value. 
For example, the data in the table is 0,10,20,30,40,20, magnification x 
2.000000 equals to the data in the table: 0,20,40,60,80,40, 
magnification x 1.000000. 
Enable the operation of E-Cam by using the same pulse frequency of 
the master axis. Magnify the magnification will enlarge the route of E-
Cam operation. The speed will be magnified as well. 
NOTE
 
This parameter can be set anytime, but will be effective only when pre-
engaged → engaged. 
 
P5-20    AC0  Acceleration/Deceleration Time (Number #0) 
Address: 0528H 
0529H 
 
Operational 
Interface: 
Panel / Software  Communication 
Related Section: 
7.10 
 
Default: 
200 
 
Control 
Mode: 
PR 
 
Unit: 
ms 
 
Range: 
1 ~ 65500 
 
Data Size: 
16-bit 
 
Format: 
Decimal 
 
Settings: 
The setting time of acceleration/deceleration in PR mode, which is the 
time it needs when accelerating from 0 to 3000r/min