ASDA-B2  Chapter 6  Control Modes of Operation 
Revision May, 2018     6-9 
Range of command pulse input: 1 / 50<Nx / M<25600 (x = 1, 2, 
3, 4)   
Electronic gear provides simple ratio change of travel distance. The high electronic gear 
ratio would cause the position command to be the stepped command. S-curve or low-
pass filter can be used to improve the situation. When electronic gear ratio is set to 1, 
the motor will turn one cycle for every 10000PUU. When electronic gear ratio is changed 
to 0.5, then every two pulses from the command will be refer to one PUU of motor 
encoder. 
For example, after setting the electronic gear ratio properly, the moving distance of the 
object is 1μm/pulse, which is easier to use. 
 
 
Gear Ratio  Moving distance of each pulse 
command 
Electronic gear is 
unapplied. 
1
1
 
m
10000
3000
25004
10003
 
Electronic gear is 
applied. 
3000
10000
 
m1