Chapter 6  Control Modes of Operation  ASDA-B2 
6-38     Revision May, 2018 
6.4.3 Smooth Torque Mode 
Related parameters: 
P1-07    TFLT 
Analog Torque Command (Low-pass 
Filter) 
Address: 010EH 
010FH 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section: 
Section 6.4.3 
 
Default: 0 
 
Control 
Mode: 
T 
 
Unit: ms 
 
Range: 0 ~ 1000 (0: Disabled) 
 
Data Size: 16-bit 
 
Display 
Format: 
Decimal 
Settings: 0: Disabled 
TFLT
Ta rge t Sp e e d
 
6.4.4 The Scaling of Analog Command 
The motor torque command is controlled by the analog voltage deviation between T_REF 
and GND and goes with parameter P1-41 to adjust the torque slope and its range.  
510
-5-10
100%
300%
-100%
-300%
Analog Input Voltage (V)
The torque control ramp is
determined by parameter P1-41
Torque command