Chapter 7 Parameters  ASDA-B2 
7-16  Revision May, 2018 
P0-10★ 
  CM2  Status Monitor Register 2 
Address: 0014H 
0015H 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section: 
4.3.5 
 
Default: - 
 
Control 
Mode: 
ALL 
 
Unit: - 
 
Range: - 
 
Data Size: 32-bit 
 
Format: Decimal 
Settings: The setting value which is set by P0-18 should be monitored via 
P0-10. Set P0-02 to 24, the panel displays “VAR-2” first, and then 
shows the content of P0-10. 
 
P0-11★ 
  CM3  Status Monitor Register 3 
Address: 0016H 
0017H 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section: 
4.3.5 
 
Default: - 
 
Control 
Mode: 
ALL 
 
Unit: - 
 
Range: - 
 
Data Size: 32-bit 
 
Format: Decimal 
Settings: The setting value which is set by P0-19 should be monitored via 
P0-11. Set P0-02 to 25, the panel displays “VAR-3” first, and then 
shows the content of P0-11. 
 
P0-12★ 
 
CM4  Status Monitor Register 4 
Address: 0018H 
0019H 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section: 
4.3.5 
 
Default: - 
 
Control 
Mode: 
ALL 
 
Unit: - 
 
Range: - 
 
Data Size: 32-bit 
 
Format: Decimal 
Settings: The setting value which is set by P0-20 should be monitored via 
P0-12. Set P0-02 to 26, the panel displays “VAR-4” first, and then 
shows the content of P0-12.