Chapter 7 Parameters  ASDA-B2 
7-48  Revision May, 2018 
P1-62    FRCL  Friction Compensation 
Address: 017CH 
017DH 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section: N/A 
 
 
Default: 0 
 
Control 
Mode: 
PT, S 
 
Unit: % 
 
Range: 0 ~ 100 
 
Data Size: 16-bit 
 
Format: Decimal 
Settings: The level of friction compensation (the percentage of rated torque. 
Set the value to 0 means to disable the function; set the value to 1 
or number above means to enable it.) 
 
P1-63    FRCT  Friction Compensation 
Address: 017EH 
017FH 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section: N/A 
 
 
Default: 0 
 
Control 
Mode: 
PT, S 
 
Unit: ms 
 
Range: 0 ~ 1000 
 
Data Size: 16-bit 
 
Format: Decimal 
Settings: Setup smoothing constant of friction compensation. 
 
P1-64 
 
Reserved 
Address: 0180H 
0181H 
 
P1-65 
 
Reserved 
Address: 0182H 
0183H 
 
P1-66 
 
Reserved 
Address: 0184H 
0185H 
 
P1-67 
 
Reserved 
Address: 0186H 
0187H