ASDA-B2  Chapter 7 Parameters 
Revision May, 2018  7-17 
P0-13★ 
  CM5  Status Monitor Register 5 
Address: 001AH 
001BH 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section: 
4.3.5 
 
Default: - 
 
Control 
Mode: 
ALL 
 
Unit: - 
 
Range: - 
 
Data Size: 32-bit 
 
Format: Decimal 
Settings: The setting value which is set by P0-21 should be monitored via 
P0-13. 
 
P0-14 
 
Reserved 
Address: 001CH 
001DH 
 
P0-15 
 
Reserved 
Address: 001EH 
001FH 
 
P0-16 
 
Reserved 
Address: 0020H 
0021H 
 
P0-17    CM1A  Status Monitor Register 1 Selection 
Address: 0022H 
0023H 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section: N/A 
 
Default: 0 
 
Control 
Mode: 
- 
 
Unit: - 
 
Range: 0 ~ 18 
 
Data Size: 16-bit 
 
Format: Decimal 
Settings: Please refer to P0-02 for its setting value. 
For example: 
If P0-17 is set to 07, then reading P0-09 means reading “Motor 
speed (r/min)”.