ASDA-B2  Chapter 7 Parameters 
Revision May, 2018  7-55 
P2-10    DI1 
DI1 Funcitonal Planning 
Address: 0214H 
0215H 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section:   
Table 7.1 
 
 
Default: 101 
 
Control 
Mode: 
ALL 
 
Unit: N/A 
 
Range: 0 ~ 0x015F   
(The last two codes are DI code) 
 
Data Size: 16-bit 
 
Format: Hexadecimal 
Settings: 
 
  Input funciton selection: Please refer to table 7.1 
  Input contact: a or b contact 
      0: Set the input contact as normally closed (b contact) 
      1: Set the input contact as normally opened (a contact) 
(P2-10 ~ P2-17 and P2-36) The setting value of function 
programmed 
When parameters are modified, please re-start the servo drive 
to ensure it can work normally. 
Note: Parameter P3-06 is used to set how digital inputs (DI) 
accepts commands, through external terminal or the 
communication which determined by P4-07. 
 
P2-11    DI2 
DI2 Funcitonal Planning 
Address: 0216H 
0217H 
 
Operation 
Interface: 
Panel/Software   Communication  
Related Section:   
Table 7.1 
 
 
Default: 104 
 
Control 
Mode: 
ALL 
 
Unit: N/A 
 
Range: 0 ~ 0x015F 
(The last two codes are DI code) 
 
Data Size: 16-bit 
 
 Format: Hexadecimal 
Settings: Please refer to the description of P2-10 
   
Input function selection 
Input contact 
Not in use