Chapter 8 Parameters ASDA-M
8-24 Revision December, 2014
P0-18 CM2A Status Monitor Register 2 Selection
Address: 0024H
0025H
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
-
Unit
-
Range
0 ~ 127
Data Size
16bit
Format
DEC
Settings
Please refer to Chapter 7.2.1, Description of Monitor Variable for
the setting value.
P0-19 CM3A Status Monitor Register 3 Selection
Address: 0026H
0027H
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
-
Unit
-
Range
0 ~ 127
Data Size
16bit
Format
DEC
Settings
Please refer to Chapter 7.2.1, Description of Monitor Variable for
the setting value.
P0-20 CM4A Status Monitor Register 4 Selection
Address: 0028H
0029H
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASD-M-0721 Series and is the answer not in the manual?

Delta ASD-M-0721 Series Specifications

General IconGeneral
BrandDelta
ModelASD-M-0721 Series
CategoryServo Drives
LanguageEnglish

Related product manuals