Chapter 8 Parameters ASDA-M
8-26 Revision December, 2014
P0-25 MAP1 Mapping Parameter # 1
Address: 0032H
0033H
Parameter
Attribute:
Parameter for individual axis
Related Section:
Section 4.3.5
Operational
Interface:
Panel / Software Communication
Default:
No need to initialize
Control
Mode:
ALL
Unit:
-
Range:
determined by the corresponding
parameter of P0-35
Data Size:
32bit
Format:
HEX
Settings:
Users can rapidly continuously read and write parameters that are
not in the same group. The content of parameter that is specified
by P0-35 will be shown in P0-25.
Please refer to the description of P0-35 for parameter setting.
P0-26 MAP2 Mapping Parameter # 2
Address: 0034H
0035H
Parameter
Attribute:
Parameter for individual axis
Related Section:
Section 4.3.5
Operational
Interface:
Panel / Software Communication
Default:
No need to initialize
Control
Mode:
ALL
Unit:
-
Range:
determined by the corresponding
parameter of P0-36
Data Size:
32bit
Format:
HEX
Settings:
The using method is the same as P0-25. The mapping target is
set by parameter P0-36.