ASDA-M Chapter 8 Parameters
Revision December, 2014 8-77
P1-79 OVLPP
The setting of the percentage of the
overlap PR path
Address: 019EH
019FH
Parameter
Attribute
Parameter for three axes
Related Section: -
Operational
Interface
Panel / Software Communication
Default
10
Control
Mode
PR
Unit
% (percentage)
Range
1 ~ 30
Data Size
32bit
Format
DEC
Settings
This parameter is for setting the percentage
of deceleration area of previous path in the
whole path during the PR path overlap.