EasyManua.ls Logo

Delta ASD-M-0721 Series - Page 405

Delta ASD-M-0721 Series
645 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8 Parameters ASDA-M
8-174 Revision December, 2014
P5-60 POV0 Target Speed Setting #0
Address: 0578H
0579H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 7.10
Operational
Interface
Panel / Software Communication
Default
20.0 200
Control
Mode
PR
Unit
1 r/min 0.1 r/min
Range
0.1 ~ 6000.0 1 ~ 60000
Data Size
16bit
Format
DEC
Example
15 = 15 r/min 150 = 15 r/min
Settings
The 1
st
target speed of PR mode
P5-61 POV1 Target Speed Setting #1
Address: 057AH
057BH
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 7.10
Operational
Interface
Panel / Software Communication
Default
50.0 500
Control
Mode
PR
Unit
1 r/min 0.1 r/min
Range
0.1 ~ 6000.0 1 ~ 60000
Data Size
16bit
Format
DEC
Example
1 = 1 r/min 10 = 1 r/min
Settings
The 2
nd
target speed of PR mode

Table of Contents

Related product manuals