Chapter 8 Parameters ASDA-M
8-182 Revision December, 2014
P5-76
CPRS CAPTURE - First Position Reset Data
Address: 0598H
0599H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 7.10
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
ALL
Unit
-
Range
-1073741824 ~ +1073741823
Data Size
32bit
Format
DEC
Settings
Please refer to the description of P5-39 X 1
P5-77
CSAX
The Position of Synchronous Capture
Axis (CAP SYNC AXES)
Address: 059AH
059BH
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
ALL
Unit
-
Range
-2147483648 ~ +2147483647
Data Size
32bit
Format
DEC
Settings
The position of this axis will synchronize with CAP signal. That is
to say, when activating CAP every two times, the motor moving
distance of this axis is the value of P5-78. (There is no
accumulative error and only in single-way operation) The
synchronous capture axis can be the source of Master.