ASDA-M Chapter 8 Parameters
Revision December, 2014 8-219
Control
Mode
PR
Unit
-
Range
-2147483648 ~ +2147483647
Data Size
32bit
Format
DEC
Settings
Please refer to the description of P6-03
P6-42 PDEF21 PATH#21 Definition
Address: 0654H
0655H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 7.10
Operational
Interface
Panel / Software Communication
Default
0x00000000
Control
Mode
PR
Unit
-
Range
0x00000000 ~ 0xFFFFFFFF
Data Size
32bit
Format
HEX
Settings
Please refer to the description of P6-02
P6-43 PDAT21 PATH#21 Data
Address: 0656H
0657H
Parameter
Attribute
Parameter for individual axis
Related Section:
Section 7.10
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
PR
Unit
-
Range
-2147483648 ~ +2147483647
Data Size
32bit
Format
DEC