Chapter 10 Troubleshooting ASDA-M
10-38 Revision December, 2014
AL127
:CANopen PDO object is
write-protected when Servo On
NMT: Reset node or 0x6040.Fault
Reset
AL128
:Error occurs when reading CANopen
PDO object via EEPROM
NMT: Reset node or 0x6040.Fault
Reset
AL129
:Error occurs when writing CANopen
PDO object via EEPROM
NMT: Reset node or 0x6040.Fault
Reset
AL130
:The accessing address of EEPROM
is out of range when using CANopen
PDO object
NMT: Reset node or 0x6040.Fault
Reset
AL131
:CRC of EEPROM calculation error
occurs when using CANopen PDO
object
NMT: Reset node or 0x6040.Fault
Reset
AL132
:Enter the incorrect password when
using CANopen PDO object
NMT: Reset node or 0x6040.Fault
Reset
AL185
:Abnormal CAN Bus hardware
NMT: Reset node or re-servo on
AL201
:An error occurs when loading
CANopen data
Turn DI.ARST on to clear the alarm.
CANopen 0x1011 Restore default
parameter
AL213
:An error occurs when writing
parameter via PR:exceeds the
range
DI.Alm Reset or P0-01= 0
AL215
:An error occurs when writing
parameter via PR:read-only
DI.Alm Reset or P0-01= 0
AL217
:An error occurs when writing
parameter via PR:parameter locked
Re-adjust PR command and
parameter
AL219
:An error occurs when writing
parameter via PR:parameter locked
Re-adjust PR command and
parameter
AL235
:PR command overflows
NMT: Reset node or 0x6040.Fault
Reset
AL245
:PR positioning is over time
NMT: Reset node or 0x6040.Fault
Reset
AL249
:The number PR command exceeds
the range
NMT: Reset node or 0x6040.Fault
Reset
AL261
:Index error occurs when accessing
CANopen object
NMT: Reset node or 0x6040.Fault
Reset
AL263
:Sub-Index error occurs when
accessing CANopen object
NMT: Reset node or 0x6040.Fault
Reset
AL265
:Data Size error occurs when
accessing CANopen object
NMT: Reset node or 0x6040.Fault
Reset