ASDA-M Chapter 8 Parameters
Revision December, 2014 8-183
P5-78 CSDS
The Interval Pulse Number between
Each Synchronous Capture Axis
Address: 059CH
059DH
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
100
Control
Mode
ALL
Unit
Pulse
Range
10 ~ +100000000
Data Size
32bit
Format
DEC
Settings
It is the moving distance of synchronous capture axis between
two CAP actions.
The new value can be written into the parameter not until CAP is
disabled (P5-39, X0=0).
P5-79
CSDS
Error Pulse Number of Synchronous
Capture Axis
Address: 059EH
059FH
Parameter
Attribute
Parameter for individual axis
Related Section: -
Operational
Interface
Panel / Software Communication
Default
0
Control
Mode
ALL
Unit
Pulse
Range
-2147483648 ~ +2147483647
Data Size
32bit
Format
DEC