ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-61
P1-23 CMOF
COMPAREOffset Data of CMP (non-volatile)
Address: 012EH
012FH
Operational
Interface
Panel / Software Communication
Related Section
Default
0
Control
Mode
ALL
Unit
Pulse unit of compare source
Range
-10000000 ~ +10000000
Data Size
32-bit
Format
Decimal
Settings
The real compared data is offset by this value.
CMP_DATA = DATA_ARRAY[*] + P1-23 + P1-24
NOTE
1P1-23: Non-volatile parameter
2P1-24: After setting, if P1-19.Z0 = 1, the value will be 0
automatically.
3CMP_DATA can be monitored via monitoring variable 0x25.
P1-24
CMOF
COMPAREOffset Data of CMP (can reset to
0 automatically)
Address: 0130H
0131H
Operational
Interface
Panel / Software Communication
Related Section:
Default
0
Control
Mode
ALL
Unit
Pulse unit of compare source
Range
-32768 ~ +32767
Data Size
16-bit
Format
Decimal
Settings
The real compared data is offset by this value.
CMP_DATA = DATA_ARRAY[*] + P1-23 + P1-24
NOTE
1P1-24: volatile parameter.
2After setting, if P1-19.Z0 = 1, the value will be 0 automatically.