EasyManua.ls Logo

Delta ECMA-C 0807 Series - Page 316

Delta ECMA-C 0807 Series
721 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-65
P1-31 Reserved
P1-32 LSTP Motor Stop Mode
Address: 0140H
0141H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
ALL
Unit
-
Range
0 ~ 0x20
Data Size
16-bit
Format
Hexadecimal
Settings
Not in use
Selection of executing dynamic brake
Not in use
Selection of executing dynamic brake: Stop Mode when Servo Off or
Alarm (including EMGS) occurs.
0: Execute dynamic brake
1: Motor free run
2: Execute dynamic brake first, then execute free run until it stops
(The motor speed is slower than P1-38).
When PL and NL occur, please refer to event time setting value of P5-
03 for determining the deceleration time. If the setting is 1 ms, it can
stop instantaneously.
P1-33 Reserved
P1-34 TACC Acceleration Constant of S-Curve
Address: 0144H
0145H
Operational
Interface
Panel / Software Communication
Related Section:
6.3.3
Default
200
Control
Mode
S
Unit
ms

Table of Contents

Related product manuals