ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-71
Settings
Set the delay time from servo ON to activate the signal of mechanical
brake (BRKR).
P1-43 MBT2 Disable Delay Time of Brake
Address: 0156H
0157H
Operational
Interface
Panel / Software Communication
Related Section:
6.5.5
Default
0
Control
Mode
ALL
Unit
ms
Range
-1000 ~ 1000
Data Size
16-bit
Format
Decimal
Settings
Set the delay time from servo OFF to switch off the signal of brake
(BRKR).
NOTE
1If the delay time of P1-43 has not finished yet and the motor speed
is slower than P1-38, the signal of brake (BRKR) will be disabled.
2If the delay time of P1-43 is up and the motor speed is higher than
P1-38, the signal of brake (BRKR) will be disabled.
3 When Servo OFF due to Alarm (except AL022) or emergency, the
setting of P1-43 is equivalent to 0 if P1-43 is set to a negative
value.
P1-44
GR1 Gear Ratio (Numerator) (N1)
Address: 0158H
0159H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.5
Default
1
Control
Mode
PTPR
Unit
Pulse
Range
1 ~ (2
29
-1)