EasyManua.ls Logo

Delta ECMA-C 0807 Series - Page 333

Delta ECMA-C 0807 Series
721 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8 Parameters ASDA-A2
8-82 Revision February, 2017
P1-63 FRCT Friction Compensation
Address: 017EH
017FH
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
PTPRS
Unit
ms
Range
0 ~ 1000
Data Size
16-bit
Format
Decimal
Settings
Setup smoothing constant of friction compensation.
P1-64 PCCT
Analog Position Command: Activation
Control
Address: 0180H
0181H
Operational
Interface
Panel/Software Communication
Related Section: N/A
Default
0x00
Control
Mode
PT
Unit
--
Range
0 x00~ 0x11
Data Size
32-bit
Format
Hexadecimal
Settings
X:
0: Disable the function of position command which is issued by
analog
1: Enable the function of position command which is issued by
analog

Table of Contents