Chapter 8 Parameters ASDA-A2
8-144 Revision February, 2017
P3-11 CANOP CANopen / DMCNET Selection
Address: 0316H
0317H
Operational
Interface:
Panel / Software Communication
Related Section:
Section 9.2
Default:
0x0000
Control
Mode:
CANopen / DMCNET
Unit:
-
Range:
Shown as below
Data Size:
16-bit
Format:
Hexadecimal
Settings:
Synchronous / DMCNET setting of CANopen is divided into X, Y, Z and
U (hexadecimal):
Item U Z Y X
Function Undefined Undefined Undefined
Whether the
parameter is saved
into EEPROM
Range -0 ~ 1 0 ~ F 0 ~ F 0 ~ 1
The definition is as follows:
X = 1: When writing parameters via PDO, parameters will be saved in
EEPROM.
X = 0: When writing parameters via PDO, parameters will not be saved
in EEPROM.
Y, Z, U : Undefined
If X is set to 1 and write parameters by PDO continuously, it will
shorten the lifetime of EEPROM.
P3-12 QSTPO CANopen / DMCNET Support Setting
Address: 0318H
0319H
Operational
Interface:
Panel / Software Communication
Related Section:
Section 9.2
Default:
0x0000
Control
Mode:
CANopen / DMCNET
Unit:
-
Range:
0x0000 ~ 0x0111
Data Size:
16-bit
Format:
Hexadecimal
NOTE