Chapter 8 Parameters ASDA-A2
8-158 Revision February, 2017
P4-20 DOF1
Offset Adjustment Value of Analog Monitor
Output (Ch1)
Address: 0428H
0429H
Operational
Interface:
Panel / Software Communication
Related Section:
6.4.4
Default:
0
Control
Mode:
ALL
Unit:
mV
Range:
-800 ~ 800
Data Size:
16-bit
Format:
Decimal
Settings:
Offset adjustment value (cannot reset)
P4-21 DOF2
Offset Adjustment Value of Analog Monitor
Output (Ch2)
Address: 042AH
042BH
Operational
Interface:
Panel / Software Communication
Related Section:
6.4.4
Default:
0
Control
Mode:
ALL
Unit:
mV
Range:
-800 ~ 800
Data Size:
16-bit
Format:
Decimal
Settings:
Offset adjustment value (cannot reset)
P4-22 SAO Analog Speed Input OFFSET
Address: 042CH
042DH
Operational
Interface:
Panel / Software Communication
Related Section: -
Default:
0
Control
Mode:
S
Unit:
mV

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ECMA-C 0807 Series and is the answer not in the manual?

Delta ECMA-C 0807 Series Specifications

General IconGeneral
BrandDelta
ModelECMA-C 0807 Series
CategoryServo Drives
LanguageEnglish

Related product manuals