ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-163
W Z Y X
Reserved Limit Setting Z pulse Setting Homing Method
- 0 ~ 1 0 ~ 2 0 ~ 8
When
encounter limit:
Z = 0: shows
error
Z = 1: rotates
backwards
Y
= 0: Stop and
return to Z
pulse
Y = 1: Go forward
to Z pulse
Y = 2: Do not look
for Z pulse
X = 7: Homing in reverse
direction
ORGP: ON > OFF, as the
homing origin
X = 8: directly define the
current position as the origin
Y = 0: Return to Z
pulse
Y = 1: Do not look
for Z pulse
X = 9: Regard the collision
point as the original point in
forward direction
X = A: Regard the collision
point as the original point in
reverse direction
P5-05 HSPD1 1
st
Speed Setting of High Speed Homing
Address: 050AH
050BH
Operational
Interface
Panel / Software Communication
Related Section: -
Default
100.0 1000
Control
Mode
(This has to be set with P5-04)
Unit
1 r/min
0.1 r/min
Range
0.1 ~ 2000.0 1 ~ 20000
Data Size
32-bit
Format
Decimal
Example
1.5 = 1.5 r/min 15 = 1.5 r/min
Settings
The 1
st
speed of high speed homing